Products














(Advanced)

Click here to contact us
(Traducir
al espanol)


  
TYPE

Water to Air 

ORIGINAL MFR

LEPEL 

MODEL

RWAG-5 

CAPACITY

5 KW 

INPUT VOLTS: 460  PHASE: 3 
FLA:      2.3  CY:        60 
REMARKS

Rebuilt 

HEAT EXCH

Radiator 


COOLING REQ'D

Air at 90 degrees ambient maximum. 

PUMP SPECS

Bronze, belt driven. 10 gpm @ 45 psig. 

FEATURES

All wetted parts are of non-ferrous materials. Rugged top accepts placement of up to a 5KW bench model induction heating unit directly onto the re-circulator. Manual motor starter. Pressure, temperature and radiator water level gauges. 

DESCRIPTION

Air cooled closed-loop re-circulating water cooling system utilizing a single motor to drive both the pump and the fan. Fully enclosed unit on wheels. 

DIMENSIONS (INCHES)

42"W x 30"D x 36"H 

Request a Quotation for This Item             Previous Model          Next Model

Back to List of Water Cooling Systems